MAGFLUX ELECTROMAGNETIC FLOWMETERS DELIVER VERY STABLE AND ACCURATE FLOW MEASUREMENTS OF PRESSURISED, CLOSED PIPE SYSTEMS.
With MJK's MagFlux electromagnetic flowmeter, you can measure flow in electrically conductive liquids in closed, pressurized pipe systems with great precision. MagFlux measures full accuracy at a fluctuation of 0.25% down to a speed of 0.2 m/sec. This not only ensures a high accuracy at low flow, but it also expands the flowmeter's dynamic measurement range. This is why high precision is also obtained even when measurements large areas.
MagFlux for fully running pipes has no moving parts, which offers the advantage that the flowmeter does not affect the pressure conditions of the pipe system. The modern modular design is flexible and can be used to measure many types of flow in conductive fluids. Due to the high data reliability, the flow meter is used widely to eliminate water waste due to leakage and as flow measurement of wastewater.
MJK sensors are easy to install. They are designed according to installation lengths ISO standards. To obtain highly qualified measurements, you just need 3x diameter straight pipe in the inlet direction and 2x diameter in the outlet direction. The sensor meets this goal for many of the smaller dimensions, giving you flexible installation options.
MagFlux flowmeters, converters and displays are produced in stainless steel and fiberglass-reinforced polyester, and therefore provide maximum protection against the environmental challenges faced by the equipment. Our measuring instruments cover a wide range of installation types and are developed with competitive specifications, so they can be combined in different way to meet specific requirements.
If you need to measure flow in very heated water or wastewater with corrosive chemicals, we recommend MagFlux 7100 with TPFE lining. This liner is made especially for process fluidswater. MagFlux is even MID certified, and, since the counters cannot be reset, the flow meter can be used to document invoicing of deliveries to or from users, as well as between systems,.
Magflux is supplied with electrodes in stainless steel, Hastelloy, platinum or titanium - with which almost any requirements can be met. The Magflux converter has outputs for both 4-20 mA, ModBus and ProfiBus - depending on the configuration. The converter can be moved up to 50 meters from the sensor. Furthermore, the converter signal can be carried up to 1000 meters to the display, which is convenient for larger facilities. A Magflux display can show data from four converters and sensors.
MagFlux from MJK is used to measure flow from boreholes to the waterworks and document the water that the borehole has delivered. Magflux is also MID certified, which means that the counter cannot be reset. MagFlux is widely used in the network from the waterworks to the end consumer. In many countries, MagFlux is used, among other things, to detect leaks when measuring night flow.
MagFlux 7200 is used for drinking water. This model has a WRAS certificate, which is an approval for drinking water measurements in i.a. England. Magflux 7200 is often used when two waterworks exchange water. As the Magflux sensor measures in both directions, you can easily calculate an overall net result.
MagFlux sensors work well in humid environments, as it can be IP68 secured without problems. You can also choose separate mounting of the converter - up to 50 meters away from the sensor. The sensor has three electrodes built-in and comes with three-point calibration, which gives a very accurate measurement with fluctuations of just 0.25% at as low a speed as 0.2 m/sec. A Magflux display can show data from four converters.
MagFlux can be used for measuring inlet and outlet water, and even for wastewater in sludge tanks. MagFlux flow meters provide accurate measurements of water entering the tanks or of the outlet water discharged via a filled pipe system. The sensor has three electrodes built-in and comes with three-point calibration. This gives a very accurate measurement with fluctuations of just 0.25% at as low a speed as 0.2 m/sec.
The Magflux converter has outputs for both 4-20 mA, ModBus and ProfiBus - depending on the configuration. The converter can be moved up to 50 meters from the sensor. Furthermore, the signal from the converter can be carried up to 1000m to the display - this is convenient for larger aquaculture facilities. The converter can be IP68 secured and thus withstand being constantly immersed in water (max. 10 meters VS) if it is to be mounted in a very humid environment. A Magflux display can show data from four converters and sensors.
If you need to measure flow in very heated water or wastewater with corrosive chemicals, we recommend MagFlux 7100 with TPFE lining. This liner is made especially for process fluidswater. MagFlux is even MID certified, and, since the counters cannot be reset, the flow meter can be used to document invoicing of deliveries to or from users, as well as between systems,.
Magflux is supplied with electrodes in stainless steel, Hastelloy, platinum or titanium - with which almost any requirements can be met. The Magflux converter has outputs for both 4-20 mA, ModBus and ProfiBus - depending on the configuration. The converter can be moved up to 50 meters from the sensor. Furthermore, the converter signal can be carried up to 1000 meters to the display, which is convenient for larger facilities. A Magflux display can show data from four converters and sensors.
Cut down the development time with drag-and-drop website builder. Drop the blocks into the page, edit content inline and publish - no technical skills required.
Choose from the large selection pre-made blocks - full-screen intro, bootstrap carousel, slider, responsive image gallery with, parallax scrolling, sticky header and more.
For accurate measurement, an MJK MagFlux electromagnetic sensor must have a filled tube.
The reduction in diameter increases the speed of the water and ensures a credible and accurate measurement.
The coning on the pipes must be mounted at least 3xdiameter before and 2xdiameter after the MagFlux sensor.
At this inlet to a wastewater treatment plant, MagFlux is used to measure the quantity delivered from trucks.
The measurement is used for invoicing the amount of wastewater processed.
These two large MagFlux sensors are mounted to measure the volume of wastewater pumped on from an underground pumping station.
Flow data from the two converters is transferred via ModBus to a more conveniently located display that shows data from both sensors.
MJK MagFlux Features
Convert With Multiple Mounting Options
MagFlux can be delivered for wall mounting or panel mounting with the converter mounted directly on the sensor. The display unit can be mounted on the converter or up to 1000 meters from the measuring point. The converter and the display can therefore be mounted where ever it is most convenient for you.
Enclosure rating Dust- and waterproof IP 67, NEMA 6 (when mounted on Converter)
Indication Indication of flow, flow direction, volume, totalizers, configuration and graph
Communication MODBUS® RTU-mode, 9600 baud, 2-wire RS 485, master-mode
Memory 32Mb Flash Memory, 345.000 entries with date, time and value Interface USB 1,1 type mini B, Female
Accuracy +/- 0,1% of reading
Measuring range Min. range = 0 - 0,2 m/s - Max. range = 0 - 10 m/s Analog output One active 4 - 20 mA, galvanically isolated (max. load 800 Ω)
Communication MODBUS® RTU-mode, 9600 baud, 2-wire RS 485, slave-mode
Power supply 24 V AC, 50 / 60 Hz ± 10 % or 115 V AC, 50 / 60 Hz ± 10 % or 230 V AC, 50 / 60 Hz ± 10 %
Enclosure rating IP 67, NEMA 6
Mounting Flange EN-1092-1 / ANSI B 16.5 / AWWA C207-01 28"-54" / AS 4087-2004 & AS 2129-2000
Housing Carbon steel, stainless steel
Flanges Carbon steel, stainless steel
Accuracy Better than ± 0,25 %
If you need to measure flow in very heated water or wastewater with corrosive chemicals, we recommend MagFlux 7100 with TPFE lining. This liner is made especially for process fluidswater. MagFlux is even MID certified, and, since the counters cannot be reset, the flow meter can be used to document invoicing of deliveries to or from users, as well as between systems,.
Magflux is supplied with electrodes in stainless steel, Hastelloy, platinum or titanium - with which almost any requirements can be met. The Magflux converter has outputs for both 4-20 mA, ModBus and ProfiBus - depending on the configuration. The converter can be moved up to 50 meters from the sensor. Furthermore, the converter signal can be carried up to 1000 meters to the display, which is convenient for larger facilities. A Magflux display can show data from four converters and sensors.
Cut down the development time with drag-and-drop website builder. Drop the blocks into the page, edit content inline and publish - no technical skills required.
Choose from the large selection pre-made blocks - full-screen intro, bootstrap carousel, slider, responsive image gallery with, parallax scrolling, sticky header and more.
MJK Support For Setup Of Magflux
MJK Support explains the initial steps of the setup of MagFlux Electromagnetic Flowmeter.
This video is in English and lasts around four minutes. The following is reviewed:
• Unpacking
• Connecting cables
• Initial firmware setup
• Calibration code
Click the picture to start the video.
You can of course set the menu to any language. See how to type the language in the menu here.
MagFlux can calculate in many different units. See how to change units here.
MagFlux can change its preferred flow direction, which means you cannot setup the flow meter incorrectly during installation.
Adjust your 4-20 mA signal to match the pump capacity and get the most optimal flow calculation.